Journal of Histochemistry and Cytochemistry Priciples for Free Access to Science
  Search:   
    >> Advanced Search

Guidelines | Subscriptions | About | exPRESS - Current - Archive | Business Information | Contact
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beverloo, H. B.
Right arrow Articles by Tanke, H. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beverloo, H. B.
Right arrow Articles by Tanke, H. J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

A comparison of the detection sensitivity of lymphocyte membrane antigens using fluorescein and phosphor immunoconjugates

HB Beverloo, A van Schadewijk, HJ Zijlmans, NP Verwoerd, J Bonnett, H Vrolijk and HJ Tanke

Department of Cytochemistry and Cytometry, Sylvius Laboratory, University of Leiden, The Netherlands.

In this study we compared the sensitivity of immunocytochemical procedures, using conventional and time-resolved fluorescent dyes, in a model system consisting of paraformaldehyde-fixed human lymphocytes. The lymphocytes were stained for the presence of the CD4 epitope by indirect immunofluorescence using FITC as label or by using time- resolved luminescent immunophosphors. These immunophosphors were primarily developed for use under time-resolved fluorescence conditions, but they are also very well suited for use in conventional fluorescence microscopes. The differently labeled cells were first examined visually with a conventional fluorescence microscope in a double-blind study. The fluorescence was also measured with a CCD camera mounted on a specially constructed time-resolved fluorescence microscope which allows the suppression of the fast decaying fluorescence, thereby permitting visualization of the specific, slowing decaying luminescence of the phosphor label. With this microscope FITC and immunophosphor labeled lymphocytes were compared under normal conditions (i.e., continuous excitation) and under conditions of time- resolved registration. Conventional fluorescence microscopy revealed a better sensitivity in favor of the phosphor conjugates. This difference became more prominent when the preparations were quantitatively assessed with the CCD-time-resolved microscope. Time-resolved microscopy permitted a suppression of fast decaying fluorescence better than 1 to 10(6).

Volume 41, Issue 5, pp. 719-725, 05/01/1993
Copyright © 1993 by The Histochemical Society


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





Guidelines | Subscriptions | About | exPRESS - Current - Archive | Business Information | Contact
The Journal of Histochemistry & Cytochemistry is owned, published, and licensed by The Histochemical Society © 1993