Widefield Microscopy Images of Tissue Sections by Computer Imaging TechniquesIsamu Ikedaa, Kazunobu Urushiharab, and Tomomichi Onoca Department of Dermatology, Mitsui Omuta Hospital, Fukuoka Japan b Research Laboratory of Photographic Engineering, Kumamoto Institute of Technology, Kumamoto Japan c Department of Dermatology, Kumamoto University School of Medicine, Kumamoto Japan Correspondence to: Isamu Ikeda, Dept. Dermatology, Mitsui Omuta Hospital, Tenryo 1-100, Omuta City, Fukuoka 836, Japan.
A fine photomicrograph covering one whole specimen is very useful in the study of skin histopathology. However, because it is almost impossible to take such a picture with a conventional photomicroscope, we attempted to make one with the aid of a computer. The large field was divided into small fields, which were individually recorded through a photomicroscope. The images were then digitized and processed with a computer to reconstruct the largefield image. A fine seamless image was reconstructed with this method. We can thus extend the field of a photomicroscope with the aid of computer imaging techniques, without impairing the quality. (J Histochem Cytochem 45:461-466, 1997) Key Words: photomicrography, computer imaging
In the study of skin histopathology, a scanning view of an entire specimen is very important in understanding of the structure of the affected area in contrast to the surrounding normal area. A fine photomicrograph covering the entire specimen would be very useful for this purpose, but it is very difficult to take such a photograph with a conventional photomicroscopy system. This is why the field of view of the photomicroscope is limited to a square covering approximately one third of an inch, even at the lowest magnification. This is large enough for normal use, but for recording a larger specimen this limitation precludes visualization of the entire object. Two approaches have been used to obtain largefield photomicrographs. One is a macrophoto technique. A photograph of the entire specimen is taken directly using a camera equipped with a macro lens. This method is simple and easy, but it has a serious weak point. Because the macro lens' depth of focus is very broad in comparison to the photomicroscope, almost the entire thickness of the specimen is recorded on the film, making it difficult to distinguish the fine structure of the specimen. This method is not suitable for many purposes. Another way to attempt a largefield image is a patchwork of printed micrographs. The large field is first divided into small parts, which are individually recorded on film. Then the micrographs are printed on paper and manually reconstructed to make the large images. In theory, the quality of the product is equal to that of a normal photomicrograph, but in practice it does not provide adequate picture quality. There are bizarre patterns of shading, irregularities of darkness, and obvious seam lines in the reconstructed picture (Figure 1).
These problems stem from the fact that a conventional photographic system cannot provide a perfect micrograph. There are always some minor errors, such as peripheral darkness or distortion in the printed images. These are not obvious when the images are viewed individually but become apparent when they are combined. The problems associated with reconstructing fine micrographs are as follows:
These errors are hard to eliminate by refining the classical photographic process; merely equalizing the darkness would entail much cost and effort. However, these errors can now be compensated for with the aid of computer imaging techniques. We decided to refine this patchwork method with the aid of a computer to improve the micrograph quality.
Materials
Digitization of the Micrographs
The developed films were scanned with the film scanner at a constant setting to transfer the images into 24-bit color image files. When a film scanner was not available, scanning printed micrographs on a flatbed scanner took the place of this process. The sampling resolution was set referring to the quality and size of the final output. For example, for a final output to a 300 ppi dye sublimination printer with a print area 10 inches long, with six individual fields composing the 10 inches, one field needs to be 500 pixels wide. A 1.4-inch-wide image on 35-mm film can be scanned in at 360 ppi. (In practice, the micrographs are overlapped to some degree, so the final output is smaller than estimated.)
The micrograph files were checked for the rotational distortion that is introduced in the scanning process. This was done with "Photoshop" software. The digitized micrographic image was displayed and magnified enough to see individual pixels. Then the image was checked to see whether its edge was overriding several columns. When the rotation was not negligible, it was compensated for by calling up the function "Rotate The micrographic images were captured at a constant position and size and were stored as picture files on a hard disk drive for later operations.
Compensation for Irregular Shading in Each Small Image (Figure 4)
A new picture (Picture B) with the same size as Picture A was created. This picture was filled with the color values that were recorded in the first step (e.g., red = 243, Green = 237, Blue = 231). Picture A was subtracted from Picture B to extract the components that were needed to compensate for the irregular shading in Picture A, as follows. First, Picture A and Picture B windows were opened, and a new picture (Picture C) of the same size as Picture A was created. Then the "Calculations" command was selected from the "Image" menu to open the dialogue box (Figure 6). Picture B was chosen as "Source 1" and Picture A as "Source 2." "Subtract" was chosen as "Blending," and the result box was set to save the result on Picture C. The channels of all pictures were set to the same color (e.g., red). This procedure was done for all color channels (red, green, and blue) with the same settings, and Picture C was saved on a hard disk drive.
In all the pictures waiting for reconstruction, their irregularity of darkness was compensated for by adding Picture C. This was done as follows. First, two windows were opened for the picture to be compensated for ("Picture X") and Picture C, and a new picture ("Picture N") with the same size as Picture X was created. Then the "Calculations" command was selected from the "Image" menu to open the dialogue box (Figure 6). Picture X was chosen as Source 1, and Picture C as Source 2. "Add" was chosen as "Blending," and the result box was set to save the result on Picture N. The channels of all pictures were set to the same color (e.g., red). This procedure was done for all color channels (red, green, and blue) with the same settings, and the compensated picture (Picture N) was saved.
Compensation for Distortion
Equalizing Irregularity of Darkness Among the Small Images
Reconstruction of a Large Image
The pattern of shading in our micrographic system is shown in Figure 7. The picture is contrast-enhanced to show the irregularity of darkness visible. This irregularity is also reflected to the wide distribution of color values shown in Figure 5.
The reconstructed image is shown in Figure 8. The entire micrograph of the tumor, as well as the surrounding normal skin, is shown without loss of its fine structure. No seam lines or shading are visible.
Full-color images provide a considerable amount of information. Ten years ago, a huge computer was needed to handle such images, but now personal computers (PCs) have enough performance to process these images ( The shading that occurred in an actual micrographic system was irregular in degree and distribution (Figure 7). It was impossible to neutralize such shading by simple peripheral brightening or manual retouching. Compensation of the light values of each pixel with an accurate correction table was needed. We obtained such a table by analyzing a blank picture, and we used it to correct the shading. In contrast to the effort required for compensation of the shading, there was almost no need to correct the distortion in the study with the film scanner. This is due in part to the absence of the enlarging and printing step, in which the images are considerably distorted. Although our method is relatively easy, great care should be taken in the digitization step because the pictures are compensated by applying the correction table created from the reference image. The position and size of capturing must be the same for the reference image and the images requiring compensation. Errors introduced during the scanning step must also be avoided because it is almost impossible to correct them afterwards. A drum should be used, if possible, to minimize the distortion and color changes at the digitizing step. The flatbed scanner is cheaper and easier to use but has some disadvantages inherent in its design. In addition to the errors introduced by the principles of digitization, the scanning process itself can introduce some distortions. Among these is the rotational distortion that occurs because one cannot place the object to be scanned exactly perpendicular to the scanning axis. This distortion can be reduced with the use of film scanners, but never eliminated.
As a solution to these problems, direct digitization of micrographs through a color charge-coupled device (CCD) camera can be considered as an alternative method. The technology of CCD cameras has progressed enough to produce fine pictures ( The patchwork method used in this study was refined enough to provide a high-quality seamless image with the aid of computer imaging techniques. Some of the steps can be automated by making corresponding plug-ins of the software "Photoshop," and we intend to make them in the future. Our method is simple and does not require special hardware or software. No manual retouching is needed in the entire process. The final products are of sufficient quality that fine structures can be visualized. The maximal resolving power and the maximal handling size of the specimen are, in theory, unlimited. We propose our method as a new way of making widefield photomicrographs.